Prototype230 V lights
The POWER Relay module switches two 230 V circuits: a ceiling light, a chandelier, LED luminaires or LED drivers. The latching relays switch at zero crossing, which spares the contacts and the LED drivers, and they do not heat up once switched. Up to 5 A per output and 5 A in total (preliminary).
POWER Relay · Manual and wiring →
PrototypeDimming 230 V lamps and LEDs
The POWER Triac module has two leading-edge dimmers for incandescent, halogen and dimmable LED lamps. You set the brightness by holding a pad, or with a swipe along the slider on the FACE Chevron panel. About 230 W per channel (preliminary). For LED lamps we are preparing the trailing-edge POWER Dimmer LED.
POWER Triac · Manual and wiring →
PrototypeLED strips
The POWER RGBW module dims 12 or 24 V LED strips: RGBW colour, tunable white CCT or up to four single-colour strips. The switch is powered from the same supply, so no 230 V has to enter the box.
POWER RGBW · Manual and wiring →
In developmentDALI
The POWER DALI module is a DALI bus master: up to 64 drivers and 16 groups over two wires, brightness, tunable white and colour. It suits larger flats, houses and offices that already have DALI or need smooth dimming of many luminaires. The bus is fed by a separate DALI supply.
POWER DALI · Manual and wiring →
In development1–10 V LED drivers
The POWER 0–10 V module switches the LED driver supply with a zero-cross relay and sets the brightness over two galvanically isolated 1–10 V lines. For office and linear luminaires with a 1–10 V control input.
POWER 0–10 V · Manual and wiring →
In developmentShutters and blinds
The POWER Blinds module drives one 230 V shutter, blind or awning motor. The relays are wired so that the phase never reaches both directions at once, and the direction only changes with the motor stopped. The switch derives the position from the calibrated travel time. The driver also handles slat tilt, sun tracking and a wind and rain lock.
POWER Blinds · Manual and wiring →
In developmentUnderfloor and electric heating
The POWER Heat Triac module switches two 230 V thermal valve actuators and measures two temperatures, turning the switch into a room thermostat. The POWER Heat Relay module switches heating cables, mats or direct heaters through a 16 A relay and meters the energy. Ratings will be added after testing.
POWER Heat Triac · POWER Heat Relay · Manual and wiring →
PrototypeButtons only, powered over the cable
The POWER Base module has no outputs. It powers the switch from PoE or 12–24 V and connects it to the network by cable. Touches, sensors and presence go to Home Assistant or a PLC, which control everything else. Ideal when there is no neutral in the box or when you prefer a reliable cable to Wi-Fi.
POWER Base · Manual and wiring →
Coming upBuilding services: 24 V inputs and outputs
The POWER PoE IO module adds four digital inputs (window contact, meter S0, 24 V), two 24 V outputs for relays and valves, two 0–10 V / 4–20 mA analogue outputs and two analogue inputs including PT1000 and NTC sensors. It is powered over PoE.
POWER PoE IO · Manual and wiring →