Standalone, no server
Scenes, the scheduler with holiday mode, the thermostat with a weekly programme, the staircase timer and auto-off, gestures, night mode, the child lock and the cleaning lock all run right in the switch. After power-up each output returns to its last state or stays off or on, as configured.
What BALANS can do →
Switch to switch
BALANS switches can link directly, without Home Assistant. One switch controls the light of another (a staircase, a long hallway) or turns off the whole flat with one touch at the door. A switch with a sensor shares the temperature with the others in the room. Messages between switches are signed, so nobody else in the network can forge them.
Home Assistant
- MQTT discovery: turn MQTT on and lights, switches, sensors and touch events (short, long, double and triple touch, very long press, two areas at once) appear in Home Assistant by themselves, placed in the room you gave the switch.
- Fault reporting: Fault and Errors entities with codes E01 to E26 and the overall Device health status. An automation can alert you that the switch lost its sensor or the network.
- LED notifications: doorbell, washing machine, open window or alarm as a blink, a pulse or a backlight colour.
- Temperature from Home Assistant: a switch without its own sensor uses the temperature you send it.
- Energy: estimated light consumption in kWh for the Energy dashboard (calculated from power and on-time).
- Updates: the firmware shows up as an update entity.
- Shutters, heating, DALI and presence are coming up with the modules in development: cover with position and slat tilt, heating zones with floor temperature, DALI groups as lights, the presence radar of the FACE Sense panel.
- Integration without MQTT is coming up: the switch offers itself in Home Assistant, an API token is all it takes.
- Assist voice satellite and widgets of the FACE Display panel are coming up: the panel detects the wake word itself and audio only goes to your Home Assistant.
MQTT
Output states, touches, the slider, sensors, faults and diagnostics as MQTT topics for Node-RED, openHAB, ioBroker or your own system. We send the topic documentation on request.
REST API, webhooks and syslog
- REST API with tokens and roles: for example a control-only token for a wall tablet or a script.
- Webhooks: on a touch the switch sends an HTTP request, so it also connects to systems without MQTT.
- Syslog: remote logging for long-term troubleshooting.
Modbus TCP and PLCs
The switch is a Modbus TCP server: coils for outputs, inputs and registers for touches, sensors, air quality, LEDs and error codes. It is off by default and is enabled in the web interface, optionally read-only and restricted to an allowed IP address.
| Controller | Function block | Status |
|---|
| Siemens S7-1500 | SCL, standard MB_CLIENT instruction | ready |
|---|
| Beckhoff TwinCAT 3 | ST, Tc2_ModbusSrv (TF6250) | coming up |
|---|
| CODESYS V3.5 | ST, ModbusFB, PLCopen XML | coming up |
|---|
| other PLCs with Modbus TCP | universal ST core (IEC 61131-3) | coming up |
|---|
The block evaluates short, long and double presses and holds without losing a press between reads, sets the pad LED colour as feedback and reads temperature, humidity, proximity and panel diagnostics.
RS485 and Modbus RTU Coming up
The CORE controller board rev C has an RS485 interface. On it the switch will be a Modbus RTU slave with the same register map as Modbus TCP. The feature is programmed and still has to be verified on the board.
DALI, 1–10 V and inputs and outputs
The POWER PoE IO module adds 24 V inputs and outputs: contacts, S0, valves, 0–10 V, 4–20 mA, PT1000. The POWER DALI (up to 64 drivers, 16 groups, brightness, tunable white and colour) and POWER 0–10 V modules are in development.
What BALANS controls →
Web interface
Built into the switch and working without internet, in Czech, Slovak, English, Polish and German.
- Setup wizard and three modes: Standard, Advanced, Expert. It works on a phone too.
- Settings change history with undo of the last change, and handover to the customer for installers.
- Settings: pad actions, touch calibration, LEDs and night brightness, scheduler, scenes, network, integrations.
- Diagnostics: temperature, humidity and air-quality charts, event log, error-code banner, backup and restore.
- Two users: an administrator and a control-only user (family, tenants).
- Login without sending the password over the network, optional HTTPS with your own certificate.
Managing several switches
A PC tool finds the switches in the network, backs up and restores settings, copies selected settings from one switch to the others, updates them in bulk and sets up new switches over USB. Each switch still verifies the firmware signature.
Updates
The firmware is updated through the web interface from a file or a URL. The update is signed; if the network and web interface do not come up afterwards, the switch rolls back to the previous version by itself. A nightly automatic update from your own server can be enabled. The firmware is supplied by the manufacturer and is not published.
Network security
The switch belongs in a separate smart-home network (VLAN). The web interface supports HTTPS. MQTT runs unencrypted in the local network. Modbus TCP is off by default. Handle remote access through Home Assistant or a VPN, not by port forwarding.