What’s new in TIA MCP
Overview of the main new features in recent versions. Minor fixes are not listed here. New versions are offered in the application as a regular update.
The current version is 2.21.0 of 21 Nov 2026 – what it brings · download
Version 2.21.0 – major update
Released on 21 November 2026 – Git and CI, releases, company standards, playbooks for AI clients and a production simulator in the virtual FAT
Git and CI for TIA projects
Connect the project to GitHub, GitLab, Azure DevOps, Gitea or Bitbucket in one step: a repository with a text export, a pipeline template and check settings. Every change runs PLC and HMI compiling, code review, an unused-object check, safety review, WinCC Unified validation and unit tests in PLCSIM Advanced. The result appears in the pull / merge request.
Releases
A version number only from a committed state and after successful checks: project archive, release notes and a Git tag. You always know exactly what is in the machine.
Company standard
The standard in tia-standard.json: block and UDT name patterns, allowed languages, tag prefixes, comments, required company library types with a minimum version and screen names. Both the AI and CI check it and return a score with advice.
Project overview
Your company's projects with the order status (quotation, engineering, FAT, commissioning, service), TIA version, released version and the results of the latest checks. Works without TIA Portal too.
Playbooks for Claude Code, Codex, Copilot and Cursor
Nine ready-made procedures – safe changes, review, Git and CI, WinCC Unified, FAT and commissioning, service, libraries and standards, migration – are installed as skills, prompts and rules for AI clients. The AI then works the same way as an experienced programmer.
Plan approval in the AI client
Claude Code, Claude Desktop or VS Code shows the plan steps and waits for your approval. The plan records that a person approved it.
Virtual FAT with a machine model
Models of a tank, heating and a conveyor with parts linked to the program. The AI verifies that the tank does not overflow, the pump does not run dry and the conveyor delivers parts – even with a simulated fault.
Machine templates
A completed specification of a conveyor line, pumping station, mixing tank, filling station or air handling unit as a project starting point, including the I/O list.
The AI picks the right tool
Tool search understands tasks written in Czech, even without diacritics. The right tool is among the first five in 98 % of the tasks in the test set, previously 64 %.
Reliability
After TIA Portal crashes or restarts, the server reconnects to the same project by itself. It finds devices by CPU name too and suggests free slots when plugging a module.
Ready for TIA Portal V21.1
TIA MCP finds the Openness interface even after an update to V21.1. TIA Portal V21.1 has not been released yet; we will verify support once it is.
Step-by-step guides
Illustrated guides in the installation: AI clients and playbooks, Git and CI, releases, project overview and standard. The web interface has a new CI and releases tab and a Projects and standard page.
In detail: Git, automatic checks and releases · Download version 2.21
Version 2.20.3
Released on 6 November 2026 – fixes based on error reports
Advice instead of errors
Missing Siemens TIA Openness group, a password-protected safety program, another open project or an import cancelled by a dialog in TIA: TIA MCP tells you what to do instead of reporting an unexpected error.
More reliable reading and import
Reading blocks in TIA Portal V17 no longer fails because of a single unreadable block, and an XML import with elements out of order is corrected and retried automatically.
LAD and FBD check
Creating LAD and FBD blocks checks the network wiring before import and says what is missing in the specification. New SCL blocks are kept even if compilation fails.
Version 2.20.2
Released on 28 October 2026 – stability and security
Clear errors
When the connection to TIA Portal is lost, tools return a clear error with advice on what to do, and the status check shows the lost connection.
Safer installation
Installation and updates with pinned, tested library versions and hash checks, and fixed vulnerabilities in web interface libraries.
More precise virtual FAT
For PID controllers, the test also checks the steady-state controller output, so it catches oscillation and saturation.
Version 2.20.1
Released 24 Oct 2026 – fixes after a full code review
Stricter permissions
All tools that change the project are now classed as write tools, and read-only mode blocks them. Online drive actions need explicit permission, F-parameters a confirmation, and restoring a backup checks that it belongs to the right project.
Privacy
Error reports now also replace block, tag and device names and argument values. Statistics and automatic reports are sent only after the notice shown after the update has been confirmed.
Dozens of fixes
STL to SCL conversion, safety and alarm reviews, SimaticML, HMI symbol migration, remote mode with the new MCP SDK, the copilot with OpenAI and Anthropic, and update rollback.
Version 2.20.0
Released 24 Oct 2026
Usage statistics
Once a day TIA MCP sends versions, the licence type and counts of starts and tool calls. They tell us what to fix and develop next. Project content, names and paths are never sent.
Automatic error reports
Unexpected errors are sent automatically after anonymisation, without licence and contact details. A previously saved choice still applies, and the mode can be changed at any time.
Under your control
Both can be switched off in the installer, on the Data and security page (which also previews the data sent) or with an environment variable. The licence agreement is now version 1.2.
Version 2.19.1
Released 21 Oct 2026 – fixes after testing version 2.19.0
HMI migration and installation
The tools for migrating faceplates and the symbol library to WinCC Unified work again in the installed version. Uninstalling removes only its own entry from AI clients.
PLCSIM Advanced from the interface
An instance registered from the web interface or by the AI no longer shuts down when the program is downloaded – unit tests and the virtual FAT run directly from the interface.
More robust screen reading
If TIA Portal crashes while a WinCC Unified screen is being read, TIA MCP remembers the spot even when the crash comes with a delay, and skips it next time. Rolling back an update now also restores the web interface.
Version 2.19
Released on 21 Oct 2026
Getting started
A status check (TIA Portal, project, write mode, licence), ten prompts to try with a Try in Copilot button and how to verify the result.
All tests in one place
Unit tests of blocks, a virtual FAT with a report, scenarios and Test Suite in PLCSIM Advanced, and the HMI test. Writing to the project only after confirmation.
Project documentation
Operating manual, handover documentation, IO list, block documentation, safety documents and text export – with download and preview.
Data and security
Write mode, what leaves the PC and when, local AI, backups and know-how protection. Automatic update checks and error reports can be set directly in the interface.
Version 2.18
Released on 21 Oct 2026
Interface in four languages
The TIA MCP web interface in Czech, English, German and Polish. A language switch, tool descriptions and copilot answers in the interface language.
Service at the machine
A page for the service technician: why the machine is down, in large type and usable on a tablet, a PDF service report and recording of intermittent faults. Read-only, writes nothing to the PLC.
Online and PLCSIM
Live values from the PLC with a trend and control of S7-PLCSIM Advanced: instances, RUN/STOP and simulation tags. Every write is confirmed.
Versions and changes
Backups with restore, a change report between project versions, Git with a text export of the project and the project history on one page.
Projects from the interface
Open, create, close and archive a project right from the web interface.
Screen previews and long tasks
A schematic preview of WinCC Unified screens, HMI test reports with screenshots of errors and the progress of long tasks with the option to cancel.
Version 2.17
Released 17 Oct 2026, update 2.17.2 on 21 Oct 2026
Step-by-step guided workflows
Project handover, finishing the migration to Unified, HMI test, a new project from a specification, virtual FAT, a check before downloading to the PLC, and service. The tools run one after another on their own and pass their results along. Writes to the project wait for your approval.
Automated HMI test in simulation
Builds a test plan from the WinCC Unified project and runs it in simulation against PLCSIM Advanced: screen navigation, buttons that write to the PLC, I/O fields and alarms. The result is a report with screenshots of failures, and the original PLC values are restored.
Tests only against a simulation
The test runs only on this PC and first checks that no machine runtime project is running. Starting the simulation and the test is always confirmed by a person; the agent cannot approve it.
Error reports to the vendor
The Report a problem button in the web GUI or a request in your AI client. You first see a preview of exactly what will be sent: an anonymised description and errors, without the project and without PLC data.
What next
A tool result recommends the next step: after an error-free compile the pre-download check, after the migration fixes the rest of the migration, after an unexpected error a report.
Web interface
Tools sorted into clear groups, saving the project and switching to another TIA Portal instance right from the GUI, code review, unused objects and an I/O checklist next to the project, and tool results ready to download. The operating manual is pre-filled from the project data.
More AI clients
TIA MCP now also registers in Visual Studio, Windsurf, Gemini CLI, LM Studio and OpenAI Codex – from the installer or from Install_Clients.bat.
Version 2.16
Released 16 Oct 2026, installer 17 Oct 2026
Windows installer
Installs without administrator rights and without Python. The wizard finds the AI clients you have installed – Claude Desktop, VS Code with Copilot, Cursor, Codex and others – and registers TIA MCP in them. Installation guide
Licence by signing in
The installer opens the Connect computer page in your browser. You enter the e-mail from your order, type in the code from the e-mail and the licence downloads by itself.
Remote access and local AI
In the wizard you enable access for ChatGPT, Claude.ai and Microsoft 365 Copilot via OAuth, or the installer downloads Ollama with a model matched to your graphics card. For roll-outs there is a silent install with parameters.
Symbol library to WinCC Unified
Symbol library objects from Comfort panels, which the TIA Portal migration turns into empty graphics, are converted by TIA MCP into dynamic SVG widgets. Drawing, rotation, mirroring, colours, appearance animations, visibility and clicks are kept. Verified on 358 symbols in three projects in TIA Portal V21.
Truncated texts after migration
Texts that end with an ellipsis after migration are measured with the Comfort font in the runtime language and fixed by removing inner margins or reducing the font size. The original state can be restored.
Alarm texts
Fixes characters in alarm texts that showed up as HTML codes after migration instead of arrows and other symbols.
Version 2.15
Released 15 Oct 2026, update 2.15.1 on 16 Oct 2026
Why has the machine stopped
Service diagnostics for maintenance: the PLC program traced back from the symptom, live values, device and terminal from the EPLAN PDF, the manual chapter and what to check. More about diagnostics
Live values from several sources
The CPU OPC UA server, the CPU web server, S7 PUT/GET including S7-300/400, PLCSIM, or a watch table filled in by the technician.
Recording of intermittent faults
Watches signals, waits for a trigger and shows what dropped first. It also evaluates a TIA Trace export.
Service report
The diagnostic result as HTML and PDF for the service records – in Czech, English, German or Polish.
Step sequences
Diagnostics follows step sequences in SCL, LAD and FBD, including transitions inside called blocks. When a transition condition is met and the step still does not advance, it points to the block that is not being executed.
A profile for service
The technician gets only reading and diagnostic tools. Nothing is written to the PLC.
Version 2.14
Released 14 October 2026
Verified online on PLCSIM Advanced 8
Download, online comparison, DB value snapshots, keeping DB values and upload were tested on the simulator with TIA V21 and V20. Nine fixes, including the correct choice of the PLCSIM interface and returning the project to offline mode after an error.
Manual with screenshots from the simulation
Screenshots of the WinCC Unified screens are added to the manual straight from the running simulation, including a short description of each screen. The simulation can be started and stopped from MCP – always only after the user confirms.
More work in the background
Compiling the whole project, text export for Git, download to the simulator, export to BAVIS, project archiving and WinCC Unified export now also run in the background – with progress and the option to cancel.
Local AI without internet
Profiles for small models in Ollama or LM Studio: few tools, short descriptions and search in the bundled documentation. Suitable for plants where the PC must not go online.
Microsoft 365 Copilot
Connect from Copilot Studio and Microsoft 365 Copilot with an API key or OAuth sign-in, a dedicated tool set for Copilot and a step-by-step guide. Without explicit permission a remote client can only read.
More reliable licence activation
Simultaneous activations of the same order are handled one after another. There are never more licences than purchased seats and no activation gets lost.
Version 2.13
Released 14 October 2026
HMI screenshots from the simulation
Screenshots of all WinCC Unified screens from a running simulation straight from the MCP server, even through a menu without text. The tool finds the menu items itself and says so when the runtime is not running.
Long operations in the background
Importing dozens of sources, compiling large PLCs and HMIs and saving run in a separate process. It survives a server restart; progress and cancellation are available at any time.
Tool profiles for every job
The new Openness V21 functions are also in the PLC, HMI and commissioning profiles, plus a new profile for drives and motion. Every profile stays within 128 tools.
Licences from your customer account
In the licence portal you issue a licence for a PC without internet, download it again, request a transfer, manage the subscription and buy more seats.
Version 2.12
Released 13 October 2026
Connections and PROFINET
S7, TCP, ISO-on-TCP and UDP connections between PLCs, integrated HMI connections for Unified and Comfort, MRP, IRT and I-Devices with transfer areas including GSD export. Modules can be moved, copied or swapped for another type while keeping their configuration.
WinCC Unified without clicking
Text and graphic lists, global scripts, native tag export and import, screen groups, rescaling screens to another resolution, validation, and dynamizations by script, expression and flashing. The screenshot plan is built automatically from the navigation.
Safety and libraries
The official collective F-signature from TIA V21, the F-program password and the F-I/O status block. For libraries: version comparison, a check for outdated instances, harmonization, clean-up and archiving of the global library.
Transactions and commissioning
Several changes in one transaction that is rolled back completely on error. Download to a memory card, .psc files, snapshots of data block values, checksums and a software comparison of two PLCs.
Drives and motion
Motor data and motor codes in Startdrive, function modules, the drive safety acceptance test report and DCC charts. Cams, interpreter programs and connecting technology objects to hardware.
OPC UA, security and Comfort
OPC UA roles and users, nodeset export, certificates and the PLC master secret. Complete export and import of Comfort panels for migration and versioning.
Version 2.11.1
Released 12 October 2026
Safer remote access
Over a remote connection (HTTP, OAuth) the agent can no longer unlock writing or confirm an action by itself. Failed sign-in attempts lock only the client they came from, and the local mode without a token rejects requests arriving through a tunnel.
Protection against planted files
A Git repository with foreign hooks or filters is refused, XML with entity declarations is not loaded and HMI screenshots are taken only within the local network.
More reliable updates
Updates now replace locked files too and remove files the new version no longer has. Version 2.11.0 and older must be updated manually once: download the ZIP and extract it over the existing installation; your licence and settings stay in place.
Copilot with Gemini
The Gemini model is chosen automatically for your API key, and an unavailable model or an exhausted quota is reported clearly.
Version 2.11
Released 4 October 2026
Virtual FAT in PLCSIM Advanced
Motors, valves, analog measurements and PID controllers are recognised in data blocks automatically and get test cases. Scenarios can also be derived from alarms, an I/O list or a state machine, tag traces are written to CSV and the result is a PDF protocol with a log.
Extended F-program review
48 rules for S7-1500F: reintegration and QBAD of F-I/O, F-addresses and discrepancy times, cycles and watchdog, uncalled F-blocks and a comparison with signatures from the previous release. It is an aid to validation and does not replace the certified procedure.
Faceplates for WinCC Unified
Templates for a motor, valve, analog value and PID. Members of UDTs and data blocks are bound to the faceplate signals and missing HMI tags come out as CSV. The result is a template screen and a procedure for converting it to a faceplate type; Openness cannot create the type itself.
Alarm review per ISA-18.2
Priority distribution, missing and duplicate texts, alarms without an operator action, limits without hysteresis and concentration on a single device. A score, findings and an XLSX for alarm rationalisation.
Live values from a real S7-1500
Reading values and the operating state and recording trends from a running PLC through the Web API, only with a trusted or pinned certificate. Writing is off by default and, even when enabled, requires a preview, a one-time token and retyping the device name.
Project skeleton from a specification
An Excel file with devices and I/O becomes a plan for approval: PLC tags, data types for a motor, valve, analog value and PID, function blocks, station DBs and compilation. Name and address collisions are checked before anything is written.
Project audit in a single call
Review of all PLCs, a check of IP addresses, PROFINET names and communication DBs across the project, and a list of unused blocks, UDTs and tags. One verdict and a report in XLSX.
Manual update after changes
After the project is edited, the source data are compared, changes are assigned to chapters and only the affected text is rewritten. A revision record and a higher document version are created.
Install into AI clients with one command
Install_Clients.bat registers TIA MCP in Claude Desktop, Cursor, VS Code and Antigravity. It changes only the tia-portal entry, backs up the original file and can be undone.
OAuth sign-in for ChatGPT and Claude
A connector is added by signing in instead of using a secret URL: dynamic client registration, PKCE and refreshable tokens. You approve access with the owner's code, and only a client with the write consent may call write tools.
Agent permissions
Three switches on the dashboard: may the agent approve plans, download to a real PLC and write values to a running PLC. Only a person can turn them on; the AI has no tool for it.
Migration: CFC, FBD, methods and GRAPH
CFC and FBD charts from PLCopen XML are converted to SCL by execution order, function block methods become separate FCs and SFC sequences become S7-GRAPH. The I/O list can also be read from AutomationML (EPLAN).
Version 2.10
Released 4 October 2026
TIA → BAVIS
A ready BAVIS visualisation project is generated from the PLC: S7 and OPC UA connections, tags with descriptions and units taken from comments, motor, valve, analog and PID objects, alarms and screens. An optional simulation mode allows a preview without a PLC.
Software handover documentation
A PDF with logo: project overview, hardware and IP addresses, call hierarchy, block descriptions, data blocks and UDTs, I/O, HMI alarms, code review result, changes since the previous release and a handover protocol for signature.
S7-1500 diagnostics via the CPU web server
Read-only: operating state, diagnostic buffer, active alarms and variable values. The password is read only from a file or an environment variable, and with an unknown certificate the password is not sent.
Version 2.9
Released 3 October 2026
“TIA-MCP Copilot” add-in for TIA Portal
A context menu in the project tree (V17 to V21): explanation, code review and documentation of blocks, tag table checks, UDT explanation or a free-form question. The add-in is read-only and opens the TIA MCP web interface.
Security and users (UMAC)
An overview of users, roles, password policy, PLC access levels and certificates. Changes to users and roles go through tools with a backup, and passwords are never passed through the chat.
Online diagnostics, upload and download with confirmation
CPU status and accessible devices, upload of a station into the project and download to a real PLC. Download is disabled by default and requires an impact preview, a one-time token and confirmation of the device name.
WinCC Unified beyond screens
HMI connections, discrete and analog alarms, alarm classes, data and alarm logs, audit trail and runtime settings.
Block fingerprints and VCI
Fingerprints of blocks, UDTs and tag tables tell a code change from a comment change. VCI workspace management and a faster rebuild of the project index were added.
Safety validation and F-parameters
Preparation of activation tests and a printout for the Safety Validation Assistant in V21, plus reading and writing the F-parameters of F-modules. The tool does not confirm test results; that is done by a person.
Help for your own blocks (Shift+F1)
For each block an HTML help page is created in the project or library: interface with comments, networks, called blocks, a sample call and AI-written texts. Only changed blocks are regenerated.