Beckhoff · B&R · CODESYS · WAGO · Schneider → Siemens

PLC migration to Siemens in days, not months

TIA MCP reads the source project of another platform and builds a TIA Portal project from it: SCL and LAD blocks, data types, global DBs, I/O tags, axes as technology objects and WinCC Unified screens. Every migration comes with a report of what is done, what needs checking and how much work remains.

source platforms
5
compile errors for the sample TwinCAT project in TIA V21
0
TIA Portal versions
V17–V21
migration report
HTML · MD

What gets converted

The conversion works on the project's source files. The result is created directly in the open TIA Portal project, compiled and checked.

ST → SCL

Programs, function blocks, functions, actions and methods. Timers, counters, edges, pointers and strings mapped to S7-1500 equivalents.

LD → LAD, SFC → SCL

Ladder into LAD networks including parallel branches. SFC sequences as an SCL state machine with step flags and times.

Data and constants

Structures as UDTs, enumerations as constants, global variables as DBs with start values and retentivity.

I/O and hardware

Inputs and outputs as PLC tags mapped into the program. An ET 200SP station proposed from the source system's I/O cards and created in the project.

Axes and Motion Control

Axes as technology objects (speed, positioning, synchronous, cams on S7-1500T), parameters from the axis configuration, leading-axis couplings. MC_* and MC_BR_* to TIA Motion Control.

HMI to WinCC Unified

TwinCAT HMI and B&R mapp View: screens, navigation, pop-ups, user controls, colour dynamizations, HMI tags, alarms and trends.

Missing libraries

When declarations from vendor libraries are missing in the source, TIA MCP infers the interface from how the code uses them and creates placeholder types. The project compiles and the report shows what to complete.

Report and effort estimate

Status of every block, tasks converted to OBs, libraries used, CPU recommendation and the remaining hours of work – before the project starts.

Alarms and texts

Messages and text lists from the HMI and PLC as WinCC Unified alarms and TIA Portal text lists.

Supported sources

PlatformProgramHMIAxes
Beckhoff TwinCAT 3✔ ST, LD, SFC✔ TwinCAT HMI✔ NC axes and parameters
B&R Automation Studio✔ ST, LD✔ mapp View✔ mapp Motion, ACP10
CODESYS and WAGO e!COCKPIT✔ PLCopen XML✖◐ SoftMotion calls
Schneider Machine Expert / Control Expert✔ ST, LD, FBD (XEF)✖◐
Allen-Bradley Studio 5000◐ L5X, ST and interfaces✖✖

✔ supported · ◐ partly · ✖ not yet. B&R Visual Components and CODESYS Visu are proprietary formats – screens are redrawn from screenshots.

How the migration works

  1. Analysis

    Reading the source project, effort estimate and report: what converts automatically and what needs an engineer.

  2. Conversion

    SCL, LAD, data types, tags, technology objects and screens are created in the TIA Portal project.

  3. Compile and review

    Compilation in TIA, error fixing and code review. The report highlights inputs written from the HMI and other risks.

  4. Verification

    Test in PLCSIM Advanced against the behaviour of the original machine, then commissioning.

No sugar-coating

What automation won't solveThe report tells you before you start.

Automatic conversion is a starting point, not a replacement for an engineer. Manual work typically remains here:

  • Vendor libraries

    Communication, recipes and special functions use different blocks in TIA. Placeholder types keep the project compilable; the logic has to be completed.

  • Motion tuning

    Axis parameters are carried over, but mechanics, drive telegrams and controller optimisation are set up on the machine.

  • Object-oriented programming

    Methods and properties are converted; interfaces and inheritance need decisions about the structure in TIA.

  • HMI graphics

    Layout and bindings are converted; images and styling need finishing in WinCC Unified.

Migration as a tool and as a service

You can run the migration yourself with a TIA MCP PRO licence, or we can do it for you turnkey including commissioning. Send us the source project and we will prepare a report with an effort estimate.