Data collection and OEE visualisation in production
A production plant with several machines and lines wanted to know how much it really produces and why machines stop. Data now comes straight from the machines, OEE is calculated per shift automatically and operators enter the reason for every stop at the machine.
- OEE calculation
- A × P × Q
- machine data
- automatic
- evaluation
- per shift
- downtime reasons
- from operators
Starting point
Production figures were written down by hand at the end of each shift. Piece counts were reconstructed afterwards, and when and why a machine stopped could only be guessed. Management wanted one figure it could trust; production wanted to know what slowed it down most.
What we delivered
- Signal collection from the machine PLCs: running, fault, good parts and scrap counts. No operator effort and no paper.
- OEE as availability × performance × quality, calculated automatically per shift, machine and whole line.
- When a machine stops, the operator panel shows a prompt and the operator picks the stop reason from a list. Short stops are told apart from breakdowns.
- A Pareto chart of downtime and scrap with reasons: you see at a glance what costs the most time.
- A big-screen overview right on the shop floor: machine status, OEE of the current shift and the order in progress.
- Shift and monthly reports for management and export to Excel.
From the original application to BAVIS
The project runs on our earlier data collection application. What proved itself there we carried over into the OEE module of BAVIS: products with ideal cycle times, orders, scrap with reasons, the stop reason prompt, OEE of machine groups and maintenance by operating hours and cycle counts. New projects therefore start from a finished, proven base.
What this means for you
- A few signals from each machine are enough to start: running, fault and piece count. Add more data once you know what to ask.
- The operator at the machine knows the stop reason best, but must enter it right away and with one tap, not at the end of the shift.
- OEE only makes sense when it is calculated the same way everywhere. That is why the calculation lives in the system, not in spreadsheets.
- The figures must be visible to production too, not just the office. A screen at the line changes what the shift talks about.
Want to know the OEE of your machines?
Send us a tag export from TIA Portal or a CSV and we will show you BAVIS with OEE on your own data. Or explore the BAVIS demo in your browser.